Samsung c61r2aee installation manual




















Ask a question. Sheila, No comments 0. Answer this question Send. Related product manuals. Can I use my pans on induction? Nowadays almost all pans are suitable for induction. You can easily test whether your old pans can also be used on induction by holding a magnet against the bottom of the pan. If the magnet stays on the pan, your old pan is suitable for induction. How do I reset my induction hob? Most induction hobs can be reset by disconnecting the hob from power by unplugging it from the power outlet.

You will then have to wait at least 60 minutes. What is a Perilex connection? Is there any chance someone could please take a look at the wiring diagram in the manual and tell me exactly how it should be wired. Thanks in advance.

The diagram and write up do say you need connecting links, usually these are supplied thin copper links that slot in if not you will need to use links. The table says for an appliance rated 25A and 32A you need to use a cable larger than 4mm squared but less than 6mm squared this would be all hobs connected via one supply cable In parts of europe cookers can be supplied by 3 phase.

Leccy , 4 Mar Hi, Thanks for your reply. No it didnt come with any links unfortunately The cable i need to use for the links, a cant use 6mm as it just wont fit. Would it be possible to use smaller cable? Or buy metal links from somewhere?

Cheers Ben. Hi, Did you manage to fix this in the end? If so, please let me know how! I am stuck with the same problem! Thanks, Ben. Hi Guys, Same problem here, just purchased this Samsung hob, and need to find these copper links, did anyone have any success in finding them, any info gratefully received, many thanks, Alan,.

Poole , 30 Oct Never seen links sold separate but have made them from copper or brass sheet metal. Leccy , 30 Oct Thanks x 1. Hi, Many thanks. They are very tiny, and are concealed in the compartment where the wiring connectors are. I can imagine that you would easily not be able to spot them, they are very concealed. Shall I wire it as 1n or 2n, and what is the difference please, thankyou again, Alan.

You need to wire it in as a single phase appliance so 1n 2n is for when you have a 2 or 3 phase supply to the property not very common in the uk. I've just found the conectors.

Can anyone tell me how they work, fit into the terminals? Found the Metal Copper U Shape links, but cannot figure out how to fit them.